5

Motor control (MCTRL)

5.13

Internal interfaces | System block "LS_MotorInterface"

256

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

bHlgLoad

BOOL

Control signal for an additional loading function of the ramp function generator

• 

L_NSet_1

.bExternalCINH

• To enable the ramp function generator to follow automatically when the

controller is inhibited, for jerk-free setpoint connection.

TRUE Set the ramp function generator to a setpoint of nHlgSetValue_a

nHlgSetValue_a

INT

Setpoint for an additional loading function of the ramp function generator

• 

L_NSet_1

.nCInhVal_a

• For speed-controlled drive tasks, the current actual speed value (e.g. in case of an

active pulse inhibit, flying restart function, controller inhibit) is provided at this

output.

• Scaling: 16384 ≡ 100 % reference speed (

C00011

)

bHlgStop

BOOL

Control signal for stopping the ramp function generator (

L_NSet_1

)

TRUE Stop the ramp function generator

bBrakeChopperActive

BOOL

(from version 12.00.00)

Status signal of the internal brake chopper control

Control of multiple internal brake choppers in the DC-bus system ( 234)

TRUE Internal brake chopper is switched-on.

nVoltageAngleAct_a

INT

(from version 13.00.00)

Current electrical voltage output angle of the controller

• Scaling: 16384 ≡ 360°

bLimSpeedTorquemodeOn

BOOL

(from version 13.00.00)

Status signal of torque control with speed limitation

TRUE Speed limitation for torque control is active.

Identifier

DIS code | data type

Value/meaning