8.4

Holding brake control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Related topics:

Behaviour in case of pulse inhibit

( 417)

Feedforward control of the motor before release

( 418)

8.4.2.3

Switching thresholds

Upper speed threshold for brake release:
Switching threshold (

C02581/1

) + hysteresis for release (

C02581/2

)

Lower speed threshold for brake application:
Switching threshold (

C02581/1

) - hysteresis for application (

C02581/3

)

Tip!
The lower speed threshold for brake application should be set to approximately 5 ... 20 % of

the maximum speed to minimise the wear of the brake and provide for an optimum brake

reaction by a low grinding of the brake.

Related topics:

Process when brake is released

( 414)

Process when brake is closed

( 415)

Stop!

Do not set the lower speed threshold for closing the brake too high to prevent excessive

wear of the brake!

Note!

When comparing speeds, only the absolute value of the motor speed and not the

direction of rotation is considered.