C00990 | flying restart fct.: activation, C00991 | flying restart fct.: process, C00992 | flying restart fct.: start frequency – Lenze 8400 StateLine User Manual

Page 772: C00993 | flying restart fct: int. time, Tivated in, C00990, The flying r, C00991, C00992, C00993

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00990

772

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00990

C00991

C00992

C00993

Parameter | Name:

C00990 | Flying restart fct.: Activation

Data type: UNSIGNED_8

Index: 23585

d

= 5C21

h

Switch on/activate flying restart circuit for non-feedback drive systems

Flying restart fct.

Selection list

(Lenze setting printed in bold)

0 Off
1 On

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00991 | Flying restart fct.: Process

Data type: UNSIGNED_16

Index: 23584

d

= 5C20

h

Selection of the starting value and the speed search range for the flying restart function

Flying restart fct.

Selection list

(Lenze setting printed in bold)

Info

0 0...+n | Start: +10 Hz

Search positive speed range (0 ... +n) with a start

frequency of +10 Hz

1 -n...0 | Start: -10 Hz

Search negative speed range (-n ... 0) with a start

frequency of -10 Hz

2 -n...+n | Start: +10 Hz

Search negative and positive speed range (-n ... n) with a

start frequency of +10 Hz

3 -n...+n | Start: -10 Hz

Search negative and positive speed range (-n ... n) with a

start frequency of -10 Hz

4 -n...+n | Start: Cx992

Search the negative and positive speed range (-n ... n)

with the start frequency set in

C00992

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00992 | Flying restart fct.: Start frequency

Data type: INTEGER_16

Index: 23583

d

= 5C1F

h

Manual selection of the starting value for the flying restart function

• Only active if

C00991

= 4

Flying restart fct.

Setting range

(min. value | unit | max. value)

Lenze setting

-200

Hz

200 10 Hz

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00993 | Flying restart fct: Int. time

Data type: UNSIGNED_16

Index: 23582

d

= 5C1E

h

Time constant of the angular difference controller of the flying restart function

• The time constant is to amount between 60 ... 300 ms.

Flying restart fct.

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

ms

6000.0 300.0 ms

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10