2 user data, User data, 11 system bus "can on board – Lenze 8400 StateLine User Manual

Page 498

Advertising
background image

11

System bus "CAN on board"

11.6

Structure of the CAN data telegram

498

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.6.2

User data

All nodes communicate by exchanging data telegrams via the system bus. The user data area of the

CAN telegram either contains network management data or parameter data or process data:

Network management data
(NMT data)

• Control information on start, stop, reset, etc. of communication to specific nodes or to all nodes

of the CAN network.

Process data
(PDOs – process data objects)

• Process data are transferred via the process data channel.
• Process data can be used to control the controller.
• Process data are not saved to the controller.
• Process data are transmitted between host system and nodes to ensure continuous exchange

of current input and output data.

• Process data usually are unscaled/scalable raw data.
• Process data are, for instance, setpoints and actual values.
• The exact meaning of the PDO file contents is determined via the function block editor (FB

Editor) in the I/O level or via the PDO mapping.

Parameter data
(SDOs – service data objects)

• Parameter data are the CANopen indexes or, in case of Lenze devices, the codes.
• Parameters are, for instance, used for one-off plant setting during commissioning or when the

material is changed on a production machine.

• Parameter data are transmitted as SDOs via the parameter data channel. They are

acknowledged by the receiver, i.e. the transmitter gets a feedback about the transmission being

successful or not.

• The parameter data channel enables access to all Lenze codes and CANopen indexes.
• Parameter changes are automatically saved to the controller until mains switching.
• In general, the parameter transfer is not time-critical.
• Parameter data are, for instance, operating parameters, diagnostic information and motor data

as well as control information on the interconnection of function blocks in the I/O level of the

FB Editor.

Advertising