2 torque control with speed limitation, Torque control with speed limitation, 5motor control (mctrl) – Lenze 8400 StateLine User Manual

Page 165

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

165

5

Motor control (MCTRL)

5.7

Sensorless vector control (SLVC)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Motor current limitation
A cross current setpoint is calculated from the torque setpoint which is limited depending on the

magnetising current, the max. current in motor mode (

C00022

) and the max. current in generator

mode (

C00023

). The total current injected into the motor does not exceed the max. currents in

motor mode and in generator mode.

Slip compensation
The slip of the machine is reconstructed using the slip model. An influencing parameter is the slip

constant (

C00021

).

Slip compensation

( 215)

5.7.2.2

Torque control with speed limitation

When bTorquemodeOn = TRUE, a torque-controlled operation is activated. The setpoint torque

directly follows the default value nTorqueSetValue_a.
Due to its speed limitation, the torque-controlled drive can only rotate within a speed range whose

positive speed is limited by nSpeedHighLimit_a and whose negative speed is limited by

nSpeedLowLimit_a.

From version 13.00.00

, the bLimSpeedTorquemodeOn status signal is used to show that the

speed limitation is active.

• The speed is defined by the process.
• The torque setpoint is calculated directly from nTorqueSetValue_a.

From version 12.00.00 onwards,

the torque limitation is active via nTorqueMotLimit_a and

nTorqueGenLimit_a in this control mode, too, for the torque setpoint to be limited. The

torque limitation can be deactivated in

C2865/1

via bit 0 to obtain the previous function.

Note!

• Absolute speed limitation to speed 0 min

-1

(nSpeedLowLimit_a or

nSpeedHighLimit_a = 0) is only possible

from version 12.00.00

.

• Quick stop (QSP) is used to switch over to

Speed control with torque limitation

.

From version 13.00.00

, the torque setpoint nSpeedSetValue_a is set to 0 by quick

stop (QSP) device-internally and the two torque limit values nTorqueMotLimit_a

and nTorqueGenLimit_a are set to 100 % to stop the drive quickly and safely

anytime. The previous behaviour can be set in

C2865/1

via bit 12 and bit 13.

Identifier

DIS code | data type

Information/possible settings

nTorqueSetValue_a

C00830/27

| INT

Torque setpoint / additive torque

• Scaling: 16384 ≡ 100 % M

max

(

C00057

)

nSpeedHighLimit_a

C00830/88

| INT

Upper speed limit for the speed limitation

• During torque-controlled operation only (bTorquemodeOn = TRUE)

• Scaling: 16384 ≡ 100 % rated speed (

C00011

)

nSpeedLowLimit_a

C00830/23

| INT

Lower speed limit for speed limitation

• During torque-controlled operation only (bTorquemodeOn = TRUE)

• Scaling: 16384 ≡ 100 % rated speed (

C00011

)

Advertising