4 parameterise application, Parameterise application, 3commissioning – Lenze 8400 StateLine User Manual

Page 64

Advertising
background image

3

Commissioning

3.8

Commissioning of the "Switch-off positioning" technology application

64

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.8.4

Parameterise application

The application parameters can be found on the right side of the Application parameter tab:

1. In the Application list field (

C00005

), select the "switch-off positioning".

After the "Switch-off positioning" application is selected, the contents of the tab change, e.g.

the Process controller and Motor potentiometer buttons are not shown any more.

2. In the Control mode list field (

C00007

) and in case of illustration

[3-2]

, for the shown switch-

off positioning without pre-switch off the "

Terminals 2

" control mode must be selected.

• The corresponding wiring diagram is displayed in a pop-up window if you click the

button

right to the list field.

• For a detailed description, see the chapter "

Terminal assignment of the control modes

".

( 309)