22 l_jogctrlextension_1, L_jogctrlextension_1, Fb: s – Lenze 8400 StateLine User Manual

Page 942: L_jogctrlextension, Bjog1in, Bjog2in, Bslowdown, Bbslowdown, 17 function library

Advertising
background image

17

Function library

17.1

Function blocks

942

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

17.1.22

L_JogCtrlExtension_1

This FB can be connected upstream to the

L_NSet

ramp function generator/setpoint generator to

implement a switch-off positioning at limit switch.

• Detailed information on this operating mode can be found in the description of the "Switch-off

positioning" TA.

Inputs

Identifier

Data type

Information/possible settings

bInputSel1

bInputSel2

BOOL

Activation of the bSlowDown1/bStop1, bSlowDown2/bStop2 and

bSlowDown3/bStop3 signal pairs according to the

Truth table

bRfgIn

BOOL

Ramping down of the setpoint generator in the downstream

L_NSet

FB according to

the

Truth table

bJog1In

bJog2In

BOOL

Selection inputs for setting fixed speeds in the setpoint generator

• If the pre-switch off is inactive (bInputSel1 and bInputSel2 are both set to FALSE),

the two control signals are output one-to-one at the bJog1Out and bJog2Out

outputs.

• To achieve the desired behaviour (starting at high speed, pre-switch off at low

speed), both inputs must be set to TRUE.

• Fixed setpoint 2 must be less than fixed setpoint 3!

Otherwise, the drive will start at a low speed and accelerate after the pre-switch

off.

• If, in addition to the bJog1In and bJog2In inputs, other jog signals are set at the

L_NSet

FB, new fixed setpoints are reached, and the drive traverses at speeds that

differ from the selection via bJog1In and bJog2In.

bSlowDown1

bSlowDown2

bSlowDown3

BOOL

Activation of fixed setpoint 2 in the downstream

L_NSet

FB

• These inputs only fulfil a function if they have been activated via bInputSel1 and

bInputSel2 previously (see

Truth table

).

bStop1

bStop2

bStop3

BOOL

Ramping down of the ramp function generator in the downstream

L_NSet

FB

• These inputs only fulfil a function if they have been activated via bInputSel1 and

bInputSel2 previously (see

Truth table

).

/B-RJ&WUO([WHQVLRQB

E,QSXW6HO

E,QSXW6HO

E5IJ,Q

E-RJ,Q

E5IJ2XW

E-RJ2XW

E-RJ2XW

E-RJ,Q

E6WRS

E6ORZ'RZQ

E6WRS

E6ORZ'RZQ

E6WRS

E6ORZ'RZQ

'08;













&75/

Advertising