1 signal adaptation by means of characteristic, Signal adaptation by means of characteristic, 6i/o terminals – Lenze 8400 StateLine User Manual

Page 284

Advertising
background image

6

I/O terminals

6.2

Analog terminals

284

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.2.1.1

Signal adaptation by means of characteristic

This function extension is only available from version 04.00.00!

According to the illustration below, an individual characteristic can be parameterised for the analog

input via the subcodes of

C00010

to provide different slopes and a dead band. Here, the input signal

corresponds to the X axis and the output signal corresponds to the Y axis:

[6-4]

Characteristic for analog inputs

In the »Engineer«, there is a parameterising dialog for entering the characteristic. This dialog also

displays the set characteristic graphically.

199.99 %

Œ

“



Ž





‘

’

y

max

-y

max

-x

max

x

max

y

min

-y

min

199.99 %

-199.99 %

-199.99 %

Parameter

Info

Lenze setting

Value Unit

C00010/1

AIN1: (+y0) = min

0.00 %

C00010/2

AIN1: (+x0) = Dead band

0.00 %

C00010/3

AIN1: (-y0) = (-min)

0.00 %

C00010/4

AIN1: (-x0) = (-Dead band)

0.00 %

C00010/5

AIN1: (+ymax)

199.99 %

C00010/6

AIN1: (+xmax)

199.99 %

C00010/7

AIN1: (-ymax)

199.99 %

C00010/8

AIN1: (-xmax)

199.99 %

Advertising