System bus "CAN on board"

11.11

Implemented CANopen objects | I-1006

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

I-1006

Setting the sync telegram cycle time.

• The cycle time can be selected as "1000" or as an integer multiple of it.
• If "0 μs"

is set (Lenze setting), no sync telegrams are created.

• This object relates to code

C00369

.

I-1014

When communication errors occur and are acknowledged or when internal errors occur in the

communication module or controller (e.g. "fault"), the system bus sends an error message. The

telegram is sent once for every error. This function can be activated or deactivated with bit 31.

[11-3] Data telegram assignment

Index:

I-1006

Name:

Communication cycle period

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: Communication cycle period

0 μs

0

μs

65535000 rw

U32

Index:

I-1014

Name:

COB-ID EMCY

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: COB-ID EMCY

0x80 + node ID

0

4294967295 rw

U32

8th byte

7th byte

6th byte

5th byte

Data 4

Data 3

Data 2

Data 1

Bit 31

Bit 30

Bit 29 ... bit 11

Bit 10 ... bit 0

0/1

0

Extended identifier*

11-bit identifier

* The extended identifier is not supported. Bit 11 ... bit 29 must be set to "0".

Bit

Setting

Bit 31

0 Emergency object is valid.
1 Emergency object is invalid.

Note!

The identifier can only be changed in the "emergency object invalid" status (bit 31 = 1).