4 unlocking the controller with a masterpin, Unlocking the controller with a masterpin, 2introduction: parameterising the controller – Lenze 8400 StateLine User Manual

Page 42

Advertising
background image

2

Introduction: Parameterising the controller

2.4

Device access protection

42

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

2.4.4

Unlocking the controller with a MasterPin

Every controller has an individual master password called "MasterPin". By entering the MasterPin, a

controller inhibited by the password mechanisms can be reset to the delivery status.

How to restore the delivery status:

1. Inhibit the controller if it is enabled, e.g. via the

C00002/16

device command.

2. Enter the MasterPin in

C00505/1

.

• The MasterPin comprises the last 6 digits of the serial number of the memory module.

3. Execute "Check MasterPin" device command

C00002/28

= "1: On / start"

Stop!

When the MasterPin is used, the parameter set is reset to the Lenze setting both in the

controller and in the memory module!

• This results in a permanent loss of the customised parameterisation that must be

recreated!

• A reset to the Lenze setting can result in unforeseen level changes at the I/O terminals

(e.g. brake control)!

Advertising