3 commissioning, Commissioning, 3commissioning – Lenze 8400 StateLine User Manual

Page 44

Advertising
background image

3

Commissioning

44

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3

Commissioning

Tip!

• Information on some of the operating statuses can quickly be obtained via the

LED

status displays

on the front of the controller.

( 421)

Check firmware: Particularly with regard to the use of older controllers (e.g. if the

customer is using one from stock) it makes sense to check the software (firmware)

version. The software version of the controller can be seen on the nameplate in the "SW"

line and can be determined by reading out code

C00099

.

Restore delivery status: Set code

C00002/1

to "1: On / start" to reset all parameter

settings of the device to the Lenze setting. This leaves you with a defined device

configuration.

Load Lenze setting

( 77)

Danger!

Unexpected motor movements can occur
Under certain conditions the motor may rotate after mains connection.
Possible consequences:

• Persons in the vicinity of the machine or plant risk getting hurt.
• Unexpected starting action may damage the machine or plant.

Protective measures:

• Commissioning with external 24 V supply and without mains voltage. In this case, the

controller can only be parameterised and diagnosed during commissioning.

• Ensure that setpoints are not active.

The following chapters describe the commissioning of the available technology

applications with the »Engineer«.
Information on how to commission using the keypad (or diagnosis terminal) can be

found in the 8400 hardware manual. The hardware manual has been stored in electronic

form on the data carrier supplied with the 8400 controller.

Advertising