11 system bus "can on board – Lenze 8400 StateLine User Manual

Page 567

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

567

11

System bus "CAN on board"

11.12

Internal interfaces | System block "LS_CANManagement"

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.12

Internal interfaces | System block "LS_CANManagement"

This function extension is only available from version 04.00.00!

The LS_CANManagement system block serves to control internal functions of the CAN driver (reset

node and re-initialisation) and to display the "Operational" status as well as the node address

(analogous to the 9300 ServoPLC and ECS devices).

Inputs

Outputs

Identifier

Data type

Information/possible settings

bResetNode

BOOL

Reset node

TRUE Carry out reset node

• If the controller is configured as CAN master in

C00352

, the NMT

command "Start Remote Node" is sent to all nodes at the bus

(broadcast telegram).

Network management telegram (NMT)

bReInitCAN

BOOL

Reinitialisation

TRUE Reinitialise "CAN on board" interface.

Identifier

Data type

Value/meaning

bFail

BOOL

Fault

TRUE An event according to the error configuration in

C00341

has

occurred

bOperational

BOOL

"Operational" status signal

TRUE The system bus is in the "Operational" status

wNodeID

WORD

Output of the node address

Note!

If a "Bus off" error is detected, the "CAN on board" interface will automatically be

reinitialised after 1 second.
Hence, 1 second after the "Bus off" has occurred, the controller will automatically be

active again on the system bus ("Auto bus off recovery").

/6B&DQ0DQDJHPHQW

E5HVHW1RGH

E5H,QLW&DQ

E)DLO

E2SHUDWLRQDO

Z1RGH,'

&* &/ &+

;



Advertising