Motor control (MCTRL)

5.10

Encoder/feedback system

220

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.10

Encoder/feedback system

For motor control with speed feedback, the feedback signal can be fed to the digital terminals

(DI1/DI2) via an HTL encoder.

[5-24] Signal flow - encoder interface

How to get to the parameterisation dialog of the encoder/feedback system:

1. »Engineer« Go to the Project view and select the 8400 StateLine controller.
2. Select the Application parameters tab from the Workspace.
3. Go to the Overview dialog level and click the following button:

4. Go to the OverviewMotor data dialog level and click the Encoder/Feedback system...

button.

Danger!

• To avoid interference when using an encoder, only use shielded motor and encoder

cables.

• If an HTL encoder is used at the digital input terminals:

Observe the maximum input frequencies of the digital inputs!

• DI1/DI2: max. 10 kHz

Note!

In the Lenze setting (e.g. when the device is delivered), the open-circuit monitoring of the

encoder is activated.

Encoder open-circuit monitoring

( 250)

Wiring diagram, assignment and electrical data of the digital input terminals can be

found in the hardware manual 8400 in the chapter "technical data". The hardware

manual is stored in electronic form on the data carrier supplied with the 8400 controller.

1

0

2

C00495

FreqIn12

C00497/1

C00051

C00420/1

C00425/1

10 kHz

C00496

Speed encoder
selection

Filter time

Encoder number of incr.

Actual speed value

Speed controller/
slip regulator

Encoder sampling time

Encoder evaluation procedure