8 ls_disfree_a, Ls_disfree_a, Sb: display of the – Lenze 8400 StateLine User Manual

Page 994: Sb: display facto, Sb: text for the display, Display, Ndis1_a, Ndis2_a, Ndis3_a, Ndis4_a

Advertising
background image

17

Function library

17.2

System blocks

994

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

17.2.8

LS_DisFree_a

This system block displays 4 arbitrary analog signals of the application on display codes.

Inputs

Parameter

Identifier

Data type

Information/possible settings

nDis1_a ... nDis4_a

INT

From version 11.00.00 onwards:

nC482_1_a ... nC482_4_a

Inputs for arbitrary analog signals of the application

Note:

From version 11.00.00

the inputs are named according to the display

parameter for an easier allocation.

Parameter

Possible settings

Info

C00482/1...4

-199.99 %

199.99 % Display of the analog signals which

are applied at the nDis1_a ... nDis4_a

inputs

C00484/1...4

...

C00487/1...4

From version 06.00.00 onwards:

Display of internal process factors in application units

Q'LVBD

&

/6B'LV)UHHBD

 & 



&

&

>

@

2IIVHW

'LVSOD\IDFWRU

7H[W

&

Q'LVBD

&  & 



&

&

>

@

&

Q'LVBD

&  & 



&

&

>

@

&

Q'LVBD

&  & 



&

&

>

@

&

8VHUXQLW

2IIVHW

'LVSOD\IDFWRU

7H[W

8VHUXQLW

2IIVHW

'LVSOD\IDFWRU

7H[W

8VHUXQLW

2IIVHW

'LVSOD\IDFWRU

7H[W

8VHUXQLW