C02218 | ls_writeparamlist: imax in generator mode, C02219 | ls_writeparamlist: dc braking: current, C02220 | ls_writeparamlist: vp speed controller – Lenze 8400 StateLine User Manual

Page 792: C02218/1, C02218/2, C02218/3, C02218/4, C02219/1, C02219/2, C02219/3

Advertising
background image

15

Parameter reference

15.2

Parameter list | C02218

792

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02218

C02219

C02220

Parameter | Name:

C02218 | LS_WriteParamList: Imax in generator mode

Data type: INTEGER_16

Index: 22357

d

= 5755

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.00

%

100.00

Subcodes

Lenze setting

Info

C02218/1

100.00 %

LS_WriteParamList

: c23_val1

C02218/2

100.00 %

LS_WriteParamList

: c23_val2

C02218/3

100.00 %

LS_WriteParamList

: c23_val3

C02218/4

100.00 %

LS_WriteParamList

: c23_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C02219 | LS_WriteParamList: DC braking: Current

Data type: INTEGER_16

Index: 22356

d

= 5754

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.00

%

200.00

Subcodes

Lenze setting

Info

C02219/1

50.00 %

LS_WriteParamList

: c36_val1

C02219/2

50.00 %

LS_WriteParamList

: c36_val2

C02219/3

50.00 %

LS_WriteParamList

: c36_val3

C02219/4

50.00 %

LS_WriteParamList

: c36_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C02220 | LS_WriteParamList: Vp speed controller

Data type: UNSIGNED_16

Index: 22355

d

= 5753

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.00

600.00

Subcodes

Lenze setting

Info

C02220/1

15.00

LS_WriteParamList

: c70_s1_val1

C02220/2

15.00

LS_WriteParamList

: c70_s1_val2

C02220/3

15.00

LS_WriteParamList

: c70_s1_val3

C02220/4

15.00

LS_WriteParamList

: c70_s1_val4

C02220/5

6.00

Reserved

C02220/6

6.00

Reserved

C02220/7

6.00

Reserved

C02220/8

6.00

Reserved

C02220/9

3.00

LS_WriteParamList

: c70_s3_val1

C02220/10

3.00

LS_WriteParamList

: c70_s3_val2

C02220/11

3.00

LS_WriteParamList

: c70_s3_val3

C02220/12

3.00

LS_WriteParamList

: c70_s3_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100