5.5

V/f characteristic control - energy-saving (VFCplusEco)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Speed variations in no-load operation and with load for

speeds > rated speed.

Minimise speed oscillations with increasing the

oscillation damping field weakening (

C00236

).

Caution: If

C00236

is increased, the maximum output

voltage of the device is reduced!

Output voltage is too low. There is a too low maximum

torque in the high field weakening range.

Reduction of the oscillation damping field weakening

(

C00236

).

Caution: When

C00236

= 0, oscillation damping field

weakening is inactive. Thus, a maximum output voltage

is available but the tendency to speed oscillations in the

field weakening range at no-load operation and with

load increases.

Drive behaviour

Remedy

Advertising