Counting behaviour
The following temporal characteristic shows the counting process depending on the signals of the

interfaces described before:

[6-1]

Transient characteristic of a quick counter block, sampling cycle = 1 ms

• The counter starts with the parameterised starting value.
• If the comparison value is reached or exceeded:

• The counter jumps back to its starting value.
• The bCount1_Compare output is set to TRUE.

• If there is a FALSE/TRUE edge at the bCountIn1_ResetCompare input, the bCountIn1_Compare

output can be reset to FALSE.

• If there is a FALSE-TRUE edge at the input bCountIn1_LoadStartValue, the current counter

content can be reset to the parameterised starting value.