I-1403/1, I-1403, 11 system bus "can on board – Lenze 8400 StateLine User Manual

Page 556

Advertising
background image

11

System bus "CAN on board"

11.11

Implemented CANopen objects | I-1403

556

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

I-1403

From version 15.00.00

Communication parameter for receiving process data via RPDO4

• For data telegram assignment and description of subindices 1 and 2, see object

I-1400

.

How to change the identifier:

1. Deactivate identifier (set bit 31 to "1").
2. Change identifier.
3. Activate identifier (set bit 31 to "0").

Index:

I-1403

Name:

RPDO4 communication parameter

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: Highest subindex supported

5

- (read access only)

ro

U8

1: COB-ID used by RPDO

0x500 + node ID

0

4294967295 rw

U32

2: Transmission type

254

0

255 rw

U8

3: Inhibit time

-

- (not used for RPDOs)

rw

U16

4: Compatibility entry

-

- (reserved, read or write access leads to error message

0x06090011)

rw

U8

5: Event timer

-

- (not used for RPDOs)

rw

U16

Subindex

Meaning

Code

0

"5" is permanently set.

• Max. 5 subindices are supported.

-

1

Identifier RPDO4

• According to the "Predefined Connection Set", the

basic setting is: Identifier = 0x500 + node ID

C00354/7

2

RPDO transmission type according to DS301 V4.02

Transmission type

( 519)

C00323/4

Advertising