C00400 | ls_pulsegenerator, C00401 | canxinout: inversion, C00401/1 – Lenze 8400 StateLine User Manual

Page 676: C00401/3, C00401/5, C00401/7, C00401/2, C00401/4, C00401/6, C00401/8

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00400

676

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00400

C00401

Parameter | Name:

C00400 | LS_PulseGenerator

Data type: UNSIGNED_16

Index: 24175

d

= 5E6F

h

Time setting of the pulse to be output by the SB

LS_PulseGenerator

Note:

The real length of the low or high level at the bSquareWave output is always 1 ms higher than set here in subcode

1 or 2. If "0 ms" is set, a level with a length of 1 ms is created length, for instance, and if "1000 ms" is set, a level with

a length of 1001 ms is created.
Setting range

(min. value | unit | max. value)

0

ms

60000

Subcodes

Lenze setting

Info

C00400/1

1000 ms

Length of the low level (break) + 1 ms

C00400/2

1000 ms

Length of the high level + 1 ms

C00400/3

100 ms

From version 06.00.00

Delay time for status signal bFirstCycleDone

• The bFirstCycleDone status signal is set to TRUE when

the first task cycle is complete and the time set here

has expired.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00401 | CANxInOut: Inversion

Data type: UNSIGNED_16

Index: 24174

d

= 5E6E

h

From version 03.00.00

This parameter serves to invert the control/status bits of the CAN port blocks.

CAN port block

Setting range

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Info

Bit 0 Active

Bit set = bit is inverted

... ...

Bit 15 Active

Subcodes

Lenze setting

Info

C00401/1

0x0000

Inversion of LP_CanIn1.bCtrl1_B0...15

C00401/2

0x0000

Inversion of LP_CanOut1.bState1_B0...15

C00401/3

0x0000

Inversion of LP_CanIn2.bIn1_B0...15

C00401/4

0x0000

Inversion of LP_CanOut2.bOut1_B0...15

C00401/5

0x0000

Inversion of LP_CanIn3.bIn1_B0...15

C00401/6

0x0000

Inversion of LP_CanOut3.bOut1_B0...15

C00401/7

0x0000

Inversion of LP_CanIn4.bIn1_B0...15

From version 15.00.00

C00401/8

0x0000

Inversion of LP_CanOut4.bOut1_B0...15

From version 15.00.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Advertising