C00242 | l_pctrl_1: operating mode, C00243 | l_pctrl_1: acceleration time influence, C00244 | l_pctrl_1: deceleration time influence – Lenze 8400 StateLine User Manual

Page 653: C00245 | l_pctrl_1: pid output value, C00242, C00243, C00244, 15 parameter reference

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

653

15

Parameter reference

15.2

Parameter list | C00242

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00242

C00243

C00244

C00245

Parameter | Name:

C00242 | L_PCTRL_1: Operating mode

Data type: UNSIGNED_8

Index: 24333

d

= 5F0D

h

The

L_PCTRL_1

FB: Selection of the operating mode

• Depending on the selection, the blue switches in the displayed signal flow are set accordingly in the Engineer on

the Application parameters tab for the

L_PCTRL_1

FB.

Selection list

(Lenze setting printed in bold)

Info

0 Off

The input setpoint nNSet_a is output without any

changes at the output nOut_a.

1 nNSet + nNSet_PID

nNSet_a and nAct_a are used as PID input values. The

arriving nNSet_a is additively linked to the value output

by the PID element.

2 nSet_PID

nSet_a and nAct_a are used as PID input values. The

input nNSet_a is not considered.

3 nNSet_PID

nNSet_a and nAct_a are used as PID input values. The

input nSet_a is not considered.

4 nNSet + nSet_PID

nSet_a and nAct_a are used as PID input values. The

arriving nNSet_a setpoint is additively linked to the value

output by the PID element.

5 nNSet || nSet_PID

nSet_a and nAct_a are used as PID input values. The

setpoint nNSet_a is output at the output nOut_a . The

PID output value is output at the output nPIDOut_a.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00243 | L_PCTRL_1: Acceleration time influence

Data type: UNSIGNED_32

Index: 24332

d

= 5F0C

h

The

L_PCTRL_1

FB: Acceleration time for showing the PID output value

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

s

999.999 5.000 s

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C00244 | L_PCTRL_1: Deceleration time influence

Data type: UNSIGNED_32

Index: 24331

d

= 5F0B

h

The

L_PCTRL_1

FB: Deceleration time for masking out the PID output value

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

s

999.999 5.000 s

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C00245 | L_PCTRL_1: PID output value

Data type: INTEGER_16

Index: 24330

d

= 5F0A

h

The

L_PCTRL_1

FB: Display of the output value of the PID process controller

Display range

(min. value | unit | max. value)

-199.99

%

199.99

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100