3.9

PC manual control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.9

PC manual control

This function extension is available from version 06.00.00 onwards and is supported by the

»Engineer« from version 2.13 onwards!

For the purpose of testing and demonstration and when an online connection has been established,

the PC manual control enables the manual control of various drive functions from the »Engineer«.

Supported drive functions:

• Speed control (follow speed setpoint)
• Activate/deactivate quick stop

More control functions:

• Reset error message

Set digital/analog outputs (in preparation)

Diagnostic functions:

• Display of the actual speed value and motor current (as time characteristic)
• Display of the current device status
• Display of the status determining error

Display of the status of the digital/analog inputs (in preparation)

3.9.1

Activate PC manual control

Stop!

PC manual control must be explicitly activated by the user.
If PC manual control is activated, the controller is inhibited via device command

(

C00002/16