C00915 | motor cable length, C00916 | motor cable cross-section, C00917 | motor cable resistance – Lenze 8400 StateLine User Manual

Page 764: C00919 | moment of inertia from load, C00919/1, C00917, C00915, C00916, Set th, Whic

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00915

764

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00915

C00916

C00917

C00919

C00922

Parameter | Name:

C00915 | Motor cable length

Data type: UNSIGNED_16

Index: 23660

d

= 5C6C

h

From version 02.00.00

Single motor cable length for calculating the motor cable resistance

• The calculated motor cable resistance is displayed in

C00917

.

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

m

1000.0 5.0 m

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10

Parameter | Name:

C00916 | Motor cable cross-section

Data type: UNSIGNED_16

Index: 23659

d

= 5C6B

h

From version 02.00.00

Motor cable cross-section of a phase/cable for calculating the motor cable resistance

• The calculated motor cable resistance is displayed in

C00917

.

Setting range

(min. value | unit | max. value)

Lenze setting

0.50

mm^2

100.00 6.00 mm^2

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00917 | Motor cable resistance

Data type: UNSIGNED_16

Index: 23658

d

= 5C6A

h

From version 02.00.00

Display of the motor cable resistance of a motor cable phase

• The motor cable resistance is calculated from the motor cable length set in

C00915

and the motor cable cross-

section set in

C00916

.

Display range

(min. value | unit | max. value)

0

mOhm

64000

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00919 | Moment of inertia from load

Data type: UNSIGNED_32

Index: 23656

d

= 5C68

h

From version 12.00.00

In order to take account of mass inertias changing during the process (e.g. reels) when optimising the response to

setpoint changes, the maximum value of the changing moment of inertia must be set here. The process signal

nInertiaAdapt_a of the

LS_MotorInterface

SB can then be used in the process to dynamically control what

percentage of it is to be taken into account for the setpoint feedforward control.
Setting range

(min. value | unit | max. value)

0.00

kg cm^2

6000000.00

Subcodes

Lenze setting

Info

C00919/1

0.00 kg cm^2

Load moment of inertia

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00922 | ICM_DiagnosticCounter

Data type: UNSIGNED_16

Index: 23653

d

= 5C65

h

This code is for device-internal use only and must not be written to by the user!

Advertising