C00621 | system connection list: bool, C00621/1, C00621/2 – Lenze 8400 StateLine User Manual

Page 716: C00621/3, C00621/4, C00621, C00621/123, C00621/124, C00621/125, 15 parameter reference

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00621

716

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00621

C00620/52

0: Not connected

LS_ParReadWrite_1

: wInLWord

Read/write request 1: Value (low word)

C00620/53

0: Not connected

LS_ParReadWrite_2

: wParIndex

Read/write request 2: Code

C00620/54

0: Not connected

LS_ParReadWrite_2

: wParSubindex

Read/write request 2: Subcode

C00620/55

0: Not connected

LS_ParReadWrite_2

: wInHWord

Read/write request 2: Value (high word)

C00620/56

0: Not connected

LS_ParReadWrite_2

: wInLWord

Read/write request 2: Value (low word)

C00620/57

0: Not connected

LS_ParReadWrite_3

: wParIndex

Read/write request 3: Code

C00620/58

0: Not connected

LS_ParReadWrite_3

: wParSubindex

Read/write request 3: Subcode

C00620/59

0: Not connected

LS_ParReadWrite_3

: wInHWord

Read/write request 3: Value (high word)

C00620/60

0: Not connected

LS_ParReadWrite_3

: wInLWord

Read/write request 3: Value (low word)

C00620/108

0: Not connected

LP_CanOut4

: wOut1

CAN4 output: Data word 1

C00620/109

0: Not connected

LP_CanOut4

: wOut2

CAN3 output: Data word 2

C00620/110

0: Not connected

LP_CanOut4

: wOut3

CAN3 output: Data word 3

C00620/111

0: Not connected

LP_CanOut4

: wOut4

CAN3 output: Data word 4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00620 | System connection list: 16-bit

Data type: UNSIGNED_16

Index: 23955

d

= 5D93

h

Parameter | Name:

C00621 | System connection list: Bool

Data type: UNSIGNED_16

Index: 23954

d

= 5D92

h

Connection parameters: Binary inputs

• Selection of the binary output signals to be connected to the binary input signals

• The selection list contains all binary output signals which can be assigned to the binary inputs mapped by the

subcodes.

• Non-listed subcodes are "reserved".

Selection list
See

selection list - digital signals

Subcodes

Lenze setting

Info

C00621/1

1001: LA_NCtrl: bDriveFail

LS_DigitalOutput

: bRelay

Digital relay output: Input signal

C00621/2

1000: LA_NCtrl: bDriveReady

LS_DigitalOutput

: bOut1

Digital output 1: Input signal

C00621/3

0: Not connected

LS_DigitalInput

: bCountIn1_Reset

Digital input 1: Reset counter

C00621/4

0: Not connected

LS_DigitalInput

: bCountIn1_LoadStartValue

Digital input 1: Load counter starting value

C00621/5

0: Not connected

LP_CanOut1

: bState_B0

CAN1 output: Status word - bit 0