7 can, 7technology applications – Lenze 8400 StateLine User Manual

Page 346

Advertising
background image

7

Technology applications

7.3

TA "actuating drive speed (AC Drive Profile)"

346

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.3.4.7

CAN

Process data assignment for fieldbus communication

( 318)

Connection

Assignment

Connection

Assignment

X101/NC-NO

LA_NCtrl.bDriveFail

X4/RFR

LA_NCtrl.bFailReset

X3/A1U

LA_NCtrl.nAuxSetValue_a *

X4/DI1

LA_NCtrl.bJogSpeed1

X3/A1I

-

X4/DI2

LA_NCtrl.bJogSpeed2

X3/O1U

LA_NCtrl.nMotorSpeedAct_a *

X4/DI3

LA_NCtrl.bSetDCBrake

* 10V ≡ 100% of reference speed (

C00011

)

X4/DI4

LA_NCtrl.bSetSpeedCcw

X4/DO1

LA_NCtrl.bDriveReady

+

=

+

+

X4

DI3

DI2

DI4

GIO

24I

DI1

RFR

24E

+

X3

AR
A1U

GA

A1I

DO1

O1U

LP_CanIn1

LP_CanOut1

wCtrl

wIn2

wIn3

DriveControl

SpeedReference

TorqueReference

wState

wOut2

wOut3

DriveControlStatus

SpeedActual

TorqueActual

wOut4 -

COM

NC

NO

X101

CG

C

L

CH

X1

*

wIn4 -

Controller enable / reset error

External

supply

24 V DC

DriveReady

Actual speed value

DriveFail

Fixed setpoint 1/3*
Fixed setpoint 2/3*

DC brake*

Change of direction of rotation*

Inputs only active
if NetCtrl=0

Speed mode:

Torque mode:

Speed setpoint

Torque setpoint

(only if NetRef=0)

Advertising