35 loop-detection, Loop, Detection – PLANET XGS3-24042 User Manual

Page 1204

Advertising
background image

76-22

Parameters:

<hold-time> is the peer-hold-time of the specified target, ranging from 1 to 65535 seconds.

Default:

Use the global configuration.

Command Mode:

Interface Configuration Mode.

Usage Guide:

LDP keeps the communication with neighbors by sending Hello to specified targets. Implementing

this command will configure the peer-hold-time of specified destination. Please pay attention to the

relationship between it and the targeted-peer-hello-time. It is recommended to set a value at least 3

times as long as the targeted-peer-hello-time. Parameters different with the global configuration can

be used when configuring the interface with this command.

Example:

Switch(config)#int vlan 9

Switch(Config-if-Vlan9)#ldp targeted-peer-hold-time 50

Related Commands:

ldp targeted-peer-hello-interval, targeted-peer-hello-interval

76.35 loop-detection

Command:

loop-detection

no loop-detection

Function:

Enable the LDP loop detection; the no operation will cancel the configuration.

Default:

The loop detection is disabled by default.

Command Mode:

LDP Protocol Configuration Mode.

Usage Guide:

LDP can be configured to enable the loop detection or not. If it is enabled, LDP provides two

methods: the first is to check whether the HOP-COUNT exceeds the upper limit; the other is to

check whether there is any repeated LSR-ID on the path vector.

Example:

Switch(config)#router ldp

Switch(config-router)#loop-detection

Advertising