21 dot1x timeout re-authperiod, 22 dot1x timeout tx-period, X timeout re – PLANET XGS3-24042 User Manual

Page 978: Authperiod, X timeout tx, Period

Advertising
background image

48-14

Global Mode.

Default:

The default value is 10 seconds.

Usage Guide:

Default value is recommended.

Example:

Setting the silent time to 120 seconds.

Switch(config)#dot1x timeout quiet-period 120

48.21 dot1x timeout re-authperiod

Command:

dot1x timeout re-authperiod <seconds>

no dot1x timeout re-authperiod

Function:

Sets the supplicant re-authentication interval; the “no dot1x timeout re-authperiod” command

restores the default setting.

Parameters:

<seconds> is the interval for re-authentication, in seconds, the valid range is 1 to 65535.

Command mode:

Global Mode.

Default:

The default value is 3600 seconds.

Usage Guide:

dot1x re-authentication must be enabled first before supplicant re-authentication interval can be

modified. If authentication is not enabled for the switch, the supplicant re-authentication interval set

will not take effect.

Example:

Setting the re-authentication time to 1200 seconds.

Switch(config)#dot1x timeout re-authperiod 1200

48.22 dot1x timeout tx-period

Command:

dot1x timeout tx-period <seconds>

Advertising