15 ethernet-oam errored-frame-seconds window, Ethernet, Oam errored – PLANET XGS3-24042 User Manual

Page 184: Frame, Seconds window

Advertising
background image

11-30

value.

Parameter:

<low-seconds>, the low detection threshold of errored frame seconds event, ranging from 1 to

65535 seconds.

Default:

1.

Command Mode:

Port mode

Usage Guide:

During the specific detection period, errored frame seconds event is induced if the number of

errored frame seconds is larger than or equal to the low threshold and the device notifies the peer

by sending event notification OAMPDU. Note that the low threshold should not be larger than the

high threshold. The definition of errored frame seconds is the second in which errored frame is

received.

Example:

Configure the low threshold of errored frame seconds event on port 1/0/4 to 100.

Switch(Config-If-Ethernet1/0/4)#ethernet-oam errored-frame-seconds threshold low 100

11.15 ethernet-oam errored-frame-seconds window

Command:

ethernet-oam errored-frame-seconds window <seconds>

no ethernet-oam errored-frame-seconds window

Function:

Configure the detection period of errored frame seconds event, no command restores the default

value.

Parameter:

<seconds>, the detection period value of errored frame seconds event, ranging from 10 to 900

secods.

Default:

60.

Command Mode:

Port mode

Usage Guide:

Detect errored frame seconds of the port after the time of specific detection period. If the number of

errored frame seconds is larger than or equal to the threshold, corresponding event is induced and