XGS3 Command Guide

1-89

1.3. Excluded active

Displayed Information

Explanation

View Name

View name

1.and1.3.

OID number

Included

The view includes sub trees rooted by this OID

Excluded

The view does not include sub trees rooted by

this OID

active

State

1.4.12 snmp-server community

Command:

snmp-server community {ro | rw} <string> [access {<num-std>|<name>}] [ipv6-access

{<ipv6-num-std>|<ipv6-name>}] [read <read-view-name>] [write <write-view-name>]

no snmp-server community <string> [access {<num-std>|<name>}] [ipv6-access

{<ipv6-num-std>|<ipv6-name>}]

Function:

Configure the community string for the switch; the “no snmp-server community <string> [access

{<num-std>|<name>}] [ipv6-access {<ipv6-num-std> |<ipv6-name>}] “command deletes the configured

community string.

Parameter:

<string> is the community string set;

ro | rw is the specified access mode to MIB, ro for read-only and rw for read-write.

<num-std> is the access-class number for standard numeric ACL, ranging between 1-99;

<name> is the access-class name for standard ACL, the character string length is ranging between 1-32;

<ipv6-num-std> is the access-class number for standard numeric IPv6 ACL, ranging between 500-599;

<name> is the access-class name for standard IPv6 ACL, the character string length is ranging between 1-32.

<read-view-name> is the name of readable view which includes 1-32 characters.

<write-view-name> is the name of writable view which includes 1-32 characters.

Command mode:

Global Mode

Usage Guide:

The switch supports up to 4 community strings. It can realize the access-control for specifically community view by

binding the community name to specifically readable view or writable view.

Example:

Add a community string named “private” with read-write permission.

Switch(config)#snmp-server community rw private