9 bfd min-echo-recv-interval, Bfd min, Echo – PLANET XGS3-24042 User Manual

Page 714: Recv, Interval

Advertising
background image

41-6

<value2>-minimum receiving interval, unit is ms, range from 200 to 1000, it may be different for

different devices.

<value3>- multiplier of session detection, range from 3 to 50.

Default:

minimum transmission interval is 400ms, minimum receiving interval is 400ms, detection multiplier

is 5.

Command Mode:

Interface configuration mode

Usage Guide:

Configure the minimum transmission interval and the multiplier of session detection for BFD control

packets. The default minimum interval is 400ms and detection multiplier is 5.

Example:

Set the minimum transmission interval and the minimum receiving interval of BFD are 800ms,

detection multiplier is 50 on interface.

s5(config)#in vlan 50

s5(config-if-vlan50)#bfd interval 800 min-rx 800 multiplier 50

s5(config-if-vlan50)#

41.9 bfd min-echo-recv-interval

Command:

bfd min-echo-receive-interval <value>

no bfd min-echo-receive-interval

Function:

Configure the minimum receiving interval for BFD control packets, no command restores its default

value.

Parameter:

<value>- minimum receiving interval, unit is ms, range from 200 to 1000, it may be different for

different devices.

Default:

minimum receiving interval is 400ms.

Command Mode:

Interface configuration mode

Usage Guide:

<value> is minimum receiving interval, unit is ms, range from 200 to 1000, it may be different for

different devices. The default minimum receiving interval is 400ms.

Example:

Advertising