Ethernet, Oam errored, Symbol – PLANET XGS3-24042 User Manual

Page 185: Period threshold high

Advertising
background image

11-31

the device notified the peer through OAMPDU.

Example:

Configure the detection period of errored frame seconds event on port 1/0/4 to 120s.

Switch(Config-If-Ethernet1/0/4)#ethernet-oam errored-frame-seconds window 120

11.16 ethernet-oam errored-symbol-period threshold

high

Command:

ethernet-oam errored-symbol-period threshold high {<high-symbols> | none}

no ethernet-oam errored-symbol-period threshold high

Function:

Configure the high threshold of errored symbol event, no command restores the default value.

Parameter:

<high-symbols>, the high detection threshold of errored symbol event, ranging from 2 to

18446744073709551615 symbols.

none, cancel the high threshold configuration.

Default:

None.

Command Mode:

Port mode

Usage Guide:

During the specific detection period, serious link event is induced if the number of errored symbols

is larger than or equal to the high threshold and the device notifies the peer by sending Information

OAMPDU of which the value of Link Fault flag in Flags field is 1. Note that the high threshold should

not be less than the low threshold.

Example:

Set the high threshold of errored symbol event on port 1/0/4 to none.

Switch(Config-If-Ethernet1/0/4)#ethernet-oam errored-symbol-period threshold high none

Advertising