Electrical installation, Operation with rated power at the 230v mains, 3/pe – Lenze E82xVxxxKxxxxx User Manual

Page 107

Advertising
background image

Electrical installation

Notes on project planning

Mains choke/mains filter assignment

6

l

107

EDS82EV903 EN 3.0

Operation with rated power at the 230V mains, 3/PE

8200 vector

Mains choke

Interference voltage category (EN 61800−3) and motor cable length

Component

Component

Type

Var.

Type

C2

Max. [m]

C1

Max. [m]

E82xV551K2C

0xx

E82ZL75132B

20

1)

2xx

E82ZZ75132B200

20

E82ZZ75132B200

20

E82ZZ75132B210

50

E82ZZ75132B210

50

E82xV751K2C

0xx

E82ZL75132B

20

1)

2xx

E82ZZ75132B200

20

E82ZZ75132B200

20

E82ZZ75132B210

50

E82ZZ75132B210

50

E82xV152K2C

0xx

E82ZL22232B

20

1)

2xx

E82ZZ22232B200

20

E82ZZ22232B200

20

E82ZZ22232B210

50

E82ZZ22232B210

50

E82xV222K2C

0xx

E82ZL22232B

20

1)

2xx

E82ZZ22232B200

20

E82ZZ22232B200

20

E82ZZ22232B210

50

E82ZZ22232B210

50

E82xV302K2C

0xx

ELN3−0120H017

20

1)

2xx

E82ZZ40232B200

20

E82ZZ40232B200

20

E82ZZ40232B210

50

E82ZZ40232B210

50

E82xV402K2C

0xx

ELN3−0120H017

20

1)

2xx

E82ZZ40232B200

20

E82ZZ40232B200

20

E82ZZ40232B210

50

E82ZZ40232B210

50

E82xV552K2C

0xx

ELN3−0120H025

20

1)

2xx

E82ZZ75232B200

20

E82ZZ75232B200

20

E82ZZ75232B210

50

E82ZZ75232B210

50

E82xV752K2C

0xx

ELN3−0088H035

20

1)

2xx

E82ZZ75232B200

20

E82ZZ75232B200

20

E82ZZ75232B210

50

E82ZZ75232B210

50

1)

The motor cable length depends on the inverter type and the switching frequency

Advertising