Safety engineering

Functional test
Important notes

14

l

498

EDS82EV903 EN 3.0

14.4

Functional test

14.4.1

Important notes

}

Danger!

Unexpected start−up of the machine possible
The "Safe torque off" safety function provides protection against an
unexpected start−up of the drive and therefore is an important item within the
safety concept for a machine. It has to be ensured that this function works
correctly.
Possible consequences:

ƒ

Death, severe injury, or damage to material assets, when the safety function
fails.

Protective measures:
After the installation and at regular intervals, the operator has to check the
function of the "Safe torque off" circuit.

ƒ

When doing this, check both disconnecting paths separately with regard to
their disconnection capability.

ƒ

The functional test can be carried out manually or automatically via the PLC.

ƒ

Basically the inspection interval depends on the application and the
corresponding risk analysis, as well as on the system as a whole. It should
not exceed 1 year.

ƒ

If the functional test shows impermissible states,
– the drive or the machine has to be shut down immediately.
– commissioning is not permitted until the safety function operates

correctly.