8 menu structure, Menu structure, Parameter setting – Lenze E82xVxxxKxxxxx User Manual

Page 245

Advertising
background image

Parameter setting

Parameter setting with the XT EMZ9371BC keypad

Menu structure

9

l

245

EDS82EV903 EN 3.0

9.3.8

Menu structure

For simple, user−friendly operation, the codes are clearly arranged in function−related
menus:

Main menu

Submenus

Description

No. Display

No.

Display

1

USER menu

Codes defined in C0517

2

Code list

All available codes

2.1

ALL

All available codes listed in ascending order (C0001 ... C7999)

2.2

Para set 1

Codes in parameter set 1 (C0001 ... C1999)

2.3

Para set 2

Codes in parameter set 2 (C2001 ... C3999)

2.4

Para set 3

Codes in parameter set 3 (C4001 ... C5999)

2.5

Para set 4

Codes in parameter set 4 (C6001 ... C7999)

2.6

Para set FIF

Codes in the function module (C1500 ... C1799)
(only for assembled function module, application I/O, Interbus,
Profibus−DP, Lecom−B, DeviceNet, CANopen)

3

Remote para

Remote parameterisation
Only active with the system bus (CAN) function module

4

Quick start

Quick commissioning of standard applications

4.1

Keypad quick

Function control
Frequency setpoint via keypad (C0140)

4.2

V/f quick

Linear V/f characteristic control
Analog frequency setpoint via potentiometer, fixed setpoints
(JOG) can be selected via terminal

4.3

VectorCtrl qu

Vector control
Analog frequency setpoint via potentiometer, fixed setpoints
(JOG) can be selected via terminal

5

Short setup

Quick configuration of predefined applications

Please observe the various key functions for changing from the
submenu to the configuration menu!

l

Press

TV until "Loading ..." is displayed:

– Change to the configuration menu, the Lenze setting is

loaded

– Required signals are linked automatically
– You must complete the configuration afterwards

l

Press

Z:

– Change to the configuration menu without linking signals
– Existing configurations can be edited

Closed−loop speed control in the "V/f characteristic control" operating mode

5.1

Speed−Ctrl 0

Analog frequency setpoint via analog input 1 (AIN1)
Digital actual frequency value via frequency input (DFIN)

5.1.1 Freq setpt

Frequency setpoint configuration

5.1.2 Actual value

Actual frequency value configuration

5.1.3 PCTRL setup

Process controller configuration

5.1.4 f limit/ramp

Output frequency, acceleration time and deceleration time
configuration

5.1.5 Motor param

Motor current control configuration, motor monitoring

Advertising