Mechanical installation – Lenze E82xVxxxKxxxxx User Manual

Page 81

Advertising
background image

Mechanical installation

Standard devices in the power range 15 ... 30 kW

Mounting with fixing brackets (standard)

5

l

81

EDS82EV903−3.0

Controller variant "3xx" (with fully mounted footprint filter)

For this mounting variant you require controller type E82EVxxxK4B3xx.

2

3

1

m

g

³

150 mm

c

k

c1

b1

³

100 mm

d1

d2

d

a

l

e

b

a

3 Nm
26.5 lb-in

h

l

0

³ 50 mm

³ 50 mm

8200vec293

Fig. 5−17

Standard installtion with fixing bracket 15 ... 30 kW



Loosen both screws to be able to remove the housing cover. The assembly kit is located under
the housing cover.

‚

Installation of mounting angles

ƒ

Dimensions

0

Arrange the controllers side by side with spacing to be able to disassemble the eyebolts.

Dimensions [mm]

8200 vector

integr. mains
filter

2)

a

b

b1

c

c1

d

d1

d2

e

1)

g

k

m

E82EV153K4B3xx

E82ZN22334B230

250

456

350

206

22

402

24

370

340

6.5

24

11

E82EV223K4B3xx

E82ZN22334B230

E82EV303K4B3xx

E82ZN30334B230

1)

If the function module is attached: observe mounting clearance and cable bending radius. The terminals of function
modules in PT design protrude above the housing by 8 mm.

2)

The integrated mains filters are only designed for controller operation at rated power. Different filters with different
dimensions are possible (

^ 106

).