Mechanical installation
Standard devices in the power range 75 ... 90 kW
Thermally separated mounting (push−through technique)
l
97
EDS82EV903−3.0
5.7.2
Thermally separated mounting (push−through technique)
For this mounting variant you require the controller type E82DV...
)
Note!
Before assembling the controller, please read the documentation for the
components connected on the supply side (mains choke, filter).
h
c1
c2
c3
c4
g
a1
a
d1
h
d2
d2
d2
d
b
b1
e1
e
8200vec303
Fig. 5−32
Dimensions for thermally separated mounting 75 ... 90 kW
Dimensions [mm]
8200 vector
a
a1
b
b1
c1
c2
c3
c4
d
d1
d2
e
1)
e1
1)
g
h
E82DV553K4B
488
450
718
680
49
172.5 295.5 419
698
49
200
285
164
9
10
E82DV553K4B
1)
If the function module is attached: observe mounting clearance and cable bending radius. The terminals of function
modules in PT design protrude above the housing by 8 mm.
Cutout in the control cabinet
Dimensions [mm]
8200 vector
Width
Height
E82DV553K4B
428.5
660
E82DV553K4B