Technical data – Lenze E82xVxxxKxxxxx User Manual
Page 56
![background image](/manuals/566070/56/background.png)
Technical data
Operation with increased rated power
Rated data for 400 V mains voltage
l
56
EDS82EV903 EN 3.0
Typical motor power
Three−phase asynchronous
motor (4−pole)
P
rated
[kW]
4.0
5.5
11
P
rated
[hp]
5.0
7.5
15
8200 vector type
EMC filter integrated
E82xV302K4C0xx
E82xV402K4C0xx
2)
E82xV752K4C0xx
2)
Without EMC filter
E82xV302K4C4xx
E82xV402K4C2xx
2)
E82xV752K4C2xx
2)
Rated mains current
without mains choke
I
mains
[A]
10.8
−
−
with mains choke
I
mains
[A]
8.4
10.6
18.0
Output power +U
DC
, −U
DC
1)
P
DCres
[kW]
0.7
0
0
Rated output
current at
switching
frequency
2 kHz sin
I
r
[A]
8.7
11.4
19.8
4 kHz sin
Max. permissible
output current for
60 s at switching
frequency
2 kHz sin
I
max
[A]
11.0
14.2
24.8
4 kHz sin
Power loss (operation with
I
N24
)
E82EV...
P
loss
[W]
145
180
300
E82DV... inside/outside
P
loss
[W]
48/97
60/120
100/200
E82CV... inside/cooler
P
loss
[W]
48/97
60/120
100/200
Dimensions
Dependent on the mounting variant (
^ 61)
Mass
E82EV...
m [kg]
2.9
3.6
E82DV...
m [kg]
2.9
3.6
E82CV...
m [kg]
2.4
3.0
1)
Power supplied by the DC bus when operating with power−adapted motor
2)
Operation only permitted with mains choke (