Extensions for automation, Terminal data, X3/28, controller inhibit (cinh) – Lenze E82xVxxxKxxxxx User Manual

Page 193: X3/e1 .... x3/e4, digital inputs, Supply via an external voltage source, X3/e1 ... x3/e4, digital inputs

Advertising
background image

Extensions for automation

I/O function module E82ZAFSCO10 (Standard I/O PT)

Installation

7

l

193

EDS82EV903 EN 3.0

Terminal data

Field

Values

Electrical connection

2−pin plug connector with spring connection

Possible connections

rigid:

1.5 mm

2

(AWG 16)

flexible:

without wire end ferrule
1.5 mm

2

(AWG 16)

with wire end ferrule, without plastic sleeve
1.5 mm

2

(AWG 16)

with wire end ferrule, with plastic sleeve
1.5 mm

2

(AWG 16)

Stripping length

9 mm

Connection plan

Supply via the internal voltage source (X3/20):

ƒ

X3/28, controller inhibit (CINH)

ƒ

X3/E1 .... X3/E4, digital inputs

62

8

9

20 28 E1 E2 E3 E4 39 A1 59

X3

GND1

GND2

+5V

+20V

8

9

7

0…+

5V

1k … 10k

AIN1

AOUT1

DIGOUT1

7

E82ZAFS001

Supply via an external voltage source:

ƒ

X3/28, controller inhibit (CINH)

ƒ

X3/E1 ... X3/E4, digital inputs

GND2

62

8

9

20 28 E1 E2 E3 E4 39 A1 59

X3

7

GND1

+5V

+20V

+

_

24 V ext.
(+12 V DC - 0% ... +30 V DC + 0%)
max. 120 mA

AIN1

AOUT1

DIGOUT1

0

…+

5

V

1k … 10k

E82ZAFS002

The min. wiring requirements for operation

Advertising