Parameter set management
Saving and copying parameter sets

10

l

370

EDS82EV903 EN 3.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0003
*

v

Saving
parameters
non−volatilely

1

0

Do not save parameters in the EEPROM Data loss after mains switch−off

1

Always save parameters in the EEPROM

l

Active after every mains
connection

l

Cyclic alteration of parameters
via bus module is not
permissible

3

Save your own basic setting in the
EEPROM

Afterwards save parameter set 1
as own basic setting with
C0002 = 9

)

Note!

ƒ

Do not remove keypad as long as the parameters are being transmitted! If
the keypad is removed during transmission, the controller indicates the
errors "Prx" or "PT5".

ƒ

A detailed description of the keypads can be found in the "Parameter
setting" chapter.

Restoring the delivery status

1. Attach keypad.

2. Inhibit controller with

s or via terminal (X3/28 = LOW).

3. Set the correct selection number in C0002 from the "Restore delivery status"

category and confirm with

v.

– E.g. C0002 = 1: Parameter set 1 of the controller is overwritten with Lenze setting.

Parameter set transfer from the controller to the keypad

1. Attach keypad.

2. Inhibit controller with

s or via terminal (X3/28 = LOW).

3. Set C0002 = 20 or 50 or 80, confirm with

v.

Parameter set transfer from the keypad to the controller

1. Attach keypad.

2. Inhibit controller with

s or via terminal (X3/28 = LOW).

3. Set the correct selection number In C0002 from the "Parameter set transfer with

keypad" category and confirm with

v.

– E.g. C0002 = 10: All parameter sets of the controller are overwritten with the

settings in the keypad.

– E.g. C0002 = 11: Parameter set 1 of the controller is overwritten with the settings

in the keypad.