Function library – Lenze E82xVxxxKxxxxx User Manual
Page 397
![background image](/manuals/566070/397/background.png)
Function library
Code table
l
397
EDS82EV903 EN 3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0145
*
v
Source of
process
controller
setpoint
0
0
Overall setpoint (PCTRL1−SET3)
Main setpoint + additional
setpoint
^ 322
1
C0181 (PCTRL1−SET2)
l
Setpoint selection not possible
via
– Fixed setpoints (JOG)
–
j function of the keypad
– C0044, C0046 and C0049
– In conjunction with
manual/remote switch−over,
skip frequencies, ramp
function generator,
additional setpoint
l
Automatic DC injection brake
(auto DCB) must be
deactivated with C0019 = 0 or
C0106 = 0
2
C0412/4 (PCTRL1−SET1)
C0148
*
s
Identifying
motor data
0
0
Ready
Only when the motor is cold!
1. Inhibit controller, wait until
drive is at standstill
2. Enter the correct values from
the motor nameplate in C0087,
C0088, C0089, C0090, C0091
3. Set C0148 = 1, confirm with
v
4. Enable controller:
The identification
– starts,
c goes out
– the motor "whistles" faintly
but it does not rotate!
– takes approx. 30 s
– is completed when
c is lit
again
5. Inhibit controller
^ 315
1
Start identification
l
V/f rated frequency (C0015), slip
compensation (C0021) and motor
stator inductance (C0092) are
calculated and saved
l
The motor stator resistance (C0084)
= total resistance of the motor cable
and motor is measured and saved