Function library

Code table

10

l

397

EDS82EV903 EN 3.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0145
*

v

Source of
process
controller
setpoint

0

0

Overall setpoint (PCTRL1−SET3)

Main setpoint + additional
setpoint

^ 322

1

C0181 (PCTRL1−SET2)

l

Setpoint selection not possible
via
– Fixed setpoints (JOG)

j function of the keypad

– C0044, C0046 and C0049
– In conjunction with

manual/remote switch−over,
skip frequencies, ramp
function generator,
additional setpoint

l

Automatic DC injection brake
(auto DCB) must be
deactivated with C0019 = 0 or
C0106 = 0

2

C0412/4 (PCTRL1−SET1)

C0148
*

s

Identifying
motor data

0

0

Ready

Only when the motor is cold!
1. Inhibit controller, wait until

drive is at standstill

2. Enter the correct values from

the motor nameplate in C0087,
C0088, C0089, C0090, C0091

3. Set C0148 = 1, confirm with

v

4. Enable controller:

The identification
– starts,

c goes out

– the motor "whistles" faintly

but it does not rotate!

– takes approx. 30 s
– is completed when

c is lit

again

5. Inhibit controller

^ 315

1

Start identification

l

V/f rated frequency (C0015), slip
compensation (C0021) and motor
stator inductance (C0092) are
calculated and saved

l

The motor stator resistance (C0084)
= total resistance of the motor cable
and motor is measured and saved