Function library

Free interconnection of analog signals

Free configuration of analog input signals

10

l

331

EDS82EV903 EN 3.0

Examples

ƒ

C0412/1 = 2

ð The frequency input is the signal source for setpoint 1 (NSET1−N1)

ƒ

C0412/5 = 23

ð CAN−IN1/word 4 is the signal source for the actual process

controller value (PCTRL−ACT)

)

Note!

The process data input words CAN−IN1.W1, CAN−IN1.W2, CAN−IN2.W1 and
CAN−IN2.W2 can be defined as analog word or as digital word (16 bit). If you
link them with internal analog signals (C0412/x = 20, 21 or 30, 31), they must
be defined as analog input words. Otherwise the controller cannot interpret
the signal correctly.