Electrical installation

Notes on project planning

Mains choke/mains filter assignment

6

l

111

EDS82EV903 EN 3.0

Operation at increased rated power on 400/500 V mains, 3/PE

8200 vector

Mains choke

Interference voltage category (EN 61800−3) and motor cable length

Component

Component

Type

Var.

Type

C2

Max. [m]

C1

Max. [m]

E82xV551K4C

0xx

EZN3A1500H003−001

20

1)

2xx

E82ZZ75134B200

20

E82ZZ75134B200

20

E82ZZ75134B210

50

E82ZZ75134B210

50

E82xV751K4C

0xx

EZN3A1500H003−001

20

1)

2xx

E82ZZ75134B200

20

E82ZZ75134B200

20

E82ZZ75134B210

50

E82ZZ75134B210

50

E82xV222K4C

0xx

ELN3−0680H006−001

20

1)

2xx

E82ZZ22234B200

20

E82ZZ22234B200

20

E82ZZ22234B210

50

E82ZZ22234B210

50

E82xV302K4C

0xx

ELN3−0500H007−001

20

1)

2xx

E82ZZ55234B200

20

E82ZZ55234B200

20

E82ZZ55234B210

50

E82ZZ55234B210

50

E82xV402K4C

0xx

ELN3−0250H013−001

20

1)

2xx

E82ZZ55234B200

20

E82ZZ55234B200

20

E82ZZ55234B210

50

E82ZZ55234B210

50

E82xV752K4C

0xx

ELN3−0150H024−001

20

1)

2xx

E82ZZ11334B200

20

E82ZZ11334B200

20

E82ZZ11334B210

50

E82ZZ11334B210

50

E82xV153K4B

2xx

ELN3−0075H045

EZN3A0080H042

25

EZN3B0080H042

50

E82ZN22334B230

50

E82ZN22334B230

10

3xx

50

10

E82xV223K4B

2xx

ELN3−0055H055

EZN3A0055H060

25

EZN3B0055H060

50

E82ZN30334B230

50

E82ZN30334B230

10

3xx

50

10

E82xV303K4B

2xx

EZN3B0055H060N003

50

3xx

50

10

E82xV453K4B

2xx

ELN3−0027H105

EZN3A0030H110

EZN3A0030H110N001

4)

25

EZN3B0030H110

50

E82ZN55334B230

50

10

5)

E82ZN55334B230

10

0

5)

3xx

50

10

E82xV553K4B

2xx

ELN3−0022H130

EZN3A0030H110

EZN3A0030H110N001

4)

25

10

3xx

50

10

E82xV753K4B

2xx

ELN3−0017H170

EZN3A0017H200

25

EZN3B0017H200

50

E82ZN90334B230

50

10

5)

E82ZN90334B230

10

0

5)

3xx

50

10

E82xV903K4B

2xx

ELN3−0014H200

EZN3A0017H200

25

EZN3B0017H200

50

3xx

50

10

1)

The motor cable length depends on the inverter type and the switching frequency

4)

For E82DV553K4B (push−through technique)

5)

at switching frequency f

ch

= 16 kHz; the interference voltage category C1 cannot be achieved