Electrical installation

Notes on project planning

Mains choke/mains filter assignment

6

l

109

EDS82EV903 EN 3.0

Interference voltage category (EN 61800−3) and motor cable length

Mains choke

8200 vector

Component

Component

Mains choke

8200 vector

Max. [m]

C1

Max. [m]

C2

Type

Var.

Type

E82xV553K4B

2xx

ELN3−0027H105

EZN3A0030H110

EZN3A0030H110N001

4)

25

EZN3B0030H110

50

E82ZN55334B230

50

10

5)

E82ZN55334B230

10

0

5)

3xx

50

10

E82xV753K4B

2xx

ELN3−0022H130

EZN3A0022H150

25

EZN3B0022H150

50

E82ZN75334B230

50

10

5)

E82ZN75334B230

10

0

5)

3xx

50

10

E82xV903K4B

2xx

ELN3−0017H170

EZN3A0017H200

25

EZN3B0017H200

50

E82ZN90334B230

50

10

5)

E82ZN90334B230

10

0

5)

3xx

50

10

1)

The motor cable length depends on the inverter type and the switching frequency

2)

Side−mounted filter

3)

Footprint filter

4)

For E82DV553K4B (push−through technique)

5)

at switching frequency f

ch

= 16 kHz; the interference voltage category C1 cannot be achieved