Thermal motor monitoring

I

2

t monitoring

10

l

357

EDS82EV903 EN 3.0

10.13

Thermal motor monitoring

10.13.1

I

2

t monitoring

Description

With the I

2

t monitoring you can monitor self−ventilated three−phase AC motors thermally

without sensors.

)

Note!

The I

2

xt function is UL−approved.

ƒ

The I

2

xt monitoring is based on a mathematical model which calculates a

thermal motor utilisation from the motor currents measured.

ƒ

In UL−approved systems no additional protective measures for the motor are
required.

ƒ

However, the I

2

xt monitoring is no full motor protection, since other

influences on the motor utilisation cannot be detected, like changed cooling
conditions (e.g. cooling air flow interrupted or too warm).

ƒ

You can only obtain full motor protection if the motor is equipped with a
PTC thermistor or a thermal contact.

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0120 I

2

t switch−off

0

0
= inactive

{1 %}

200 Reference: apparent motor

current (C0054)
Reference to active motor current
(C0056) possible, see C0310