Function library

Process controller
Select the setpoint source for the process controller

10

l

322

EDS82EV903 EN 3.0

10.9.2

Select the setpoint source for the process controller

Description

Selection of a frequency setpoint for the process controller, e.g. for

ƒ

the dancer position for a dancer position control in a line drive.

ƒ

the pressure setpoint for a pressure control.

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0138
*

Process
controller
setpoint 1
(PCTRL1−SET1)

0.00

−650.00

{0.02

Hz}

650.00 The set value will be lost during

mains switching!

l

Selection if C0412/4 =
FIXED−FREE

l

Display if C0412/4

¹

FIXED−FREE

^ 322

C0181
*

Process
controller
setpoint 2
(PCTRL1−SET2)

0.00

−650.00

{0.02

Hz}

650.00

^ 322

C0145
*

v

Source of
process
controller
setpoint

0

0

Overall setpoint (PCTRL1−SET3)

Main setpoint + additional
setpoint

^ 322

1

C0181 (PCTRL1−SET2)

l

Setpoint selection not possible
via
– Fixed setpoints (JOG)

j function of the keypad

– C0044, C0046 and C0049
– In conjunction with

manual/remote switch−over,
skip frequencies, ramp
function generator,
additional setpoint

l

Automatic DC injection brake
(auto DCB) must be
deactivated with C0019 = 0 or
C0106 = 0

2

C0412/4 (PCTRL1−SET1)

Selection

Process controller setpoint = Total setpoint

C0145 = 0

Process controller setpoint = Total setpoint (PCTRL1−SET3)

Select C0145 = 0 if the setpoint is to be selected

ƒ

via JOG values,

ƒ

via keypad (C0140, function

j),

ƒ

for operation with manual/remote changeover, skip frequencies, ramp function
generator or additional setpoint,

ƒ

via parameter channel (C0044, C0046, C0049).