3 selection of the brake resistors, Selection of the brake resistors, Braking operation – Lenze E82xVxxxKxxxxx User Manual
Page 490
![background image](/manuals/566070/490/background.png)
Braking operation
Braking operation with external brake resistor
Selection of the brake resistors
l
490
EDS82EV903 EN 3.0
13.2.3
Selection of the brake resistors
The recommended Lenze brake resistors are adapted to the corresponding controller (with
regard to 150 % of regenerative power). They are suitable for most of the applications.
For special applications, e.g. centrifuges, the brake resistor must meet the following
criteria:
Brake resistor
Application
Criterion
With active load
With passive load
Continuous braking power
[W]
w P
max
@ h
e
@ h
m
@
t
1
t
zykl
w
P
max
@ h
e
@ h
m
2
@
t
1
t
zykl
Heat quantity [Ws]
w P
max
@ h
e
@ h
m
@ t
1
w
P
max
@ h
e
@ h
m
2
@ t
1
Resistance [
Ω]
R
min
v R v
U
DC
2
P
max
@ h
e
@ h
m
Active load
Can start to move independent of the drive
(e.g. unwinder)
Passive load
Can stop independent of the drive
(e.g. horizontal travelling drives, centrifuges, fans)
V
DC
[V]
Brake chopper switching threshold from C0174
P
max
[W]
Maximum occurring braking power determined by the application
h
e
Electrical efficiency (controller + motor)
Guide value: 0.54 (0.25 kW) ... 0.85 (11 kW)
h
m
Mechanical efficiency (gearbox, machine)
t
1
[s]
Braking time
t
cycl
[s]
Cycle time = time between two successive braking processes (= t
1
+ dead time)
R
min
[
W]
Minimum permissible brake resistance (see rated data of the integrated brake chopper)