Function library – Lenze E82xVxxxKxxxxx User Manual
Page 429
Function library
Code table
l
429
EDS82EV903 EN 3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0423
*
(A)
Delay of digital
outputs
0.000
{0.001 s}
65.000 "Debouncing" of the digital
outputs
(from version: application I/O
E82ZAFA ... Vx11)
l
Switches the digital output if
the linked signal is still active
after the time set.
l
The digital output is reset
without delay
^ 348
1 Device version
151:
relay output K1
(RELAY)
Device version
152, 153:
Digital
switching
output K1
0.000
2 Digital output
X3/A1
(DIGOUT1)
0.000
3 Digital output
X3/A2
(DIGOUT2)
0.000
C0424
*
v
(A)
Output signal
range − analog
outputs
Application I/O
0
1
0 ... 10 V / 0 ... 20 mA
4 ... 20 mA
Observe jumper position of the
function module!
(from version: application I/O
E82ZAFA ... Vx11)
^ 332
1 X3/62 (AOUT1)
0
2 X3/63 (AOUT2)
0