Function library

Free interconnection of analog signals
Free configuration of analog process data output words

10

l

342

EDS82EV903 EN 3.0

Examples

ƒ

C0421/3

ð 5: The monitoring signal Motor voltage" is the signal source for

CAN−OUT1/word1.

ƒ

C0421/8

ð 61: The process data input wordCAN−IN2/word2 is the signal source for

CAN−OUT2/word 2.

)

Note!

ƒ

The process data output words CAN−OUT1.W1/FIF−OUT.W1, CAN−OUT2.W1
and FIF−OUT.W2 can also be assigned to C0417 and C0418 with 16 bit status
information each:
– With digital configuration under C0417 or C0418 no simultaneous analog

assignment with C0421 (C0421/x = 255)!

– With analog configuration under C0421 no simultaneous digital

assignment with C0417 and C0418 (C0417/x = 255, C0418/x = 255)!

– Otherwise the output signal would be incorrect.

ƒ

The process data input words CAN−IN1.W1/FIF−IN.W1,
CAN−IN1.W2/FIF−IN.W2, CAN−IN2.W1 and CAN−IN2.W2 can be defined as
analog word or digital word (16 bit). If you link them with analog process
data output words (C0421/x = 50, 51 or 60, 61), they must be defined as
analog input words. Otherwise the output signal would be incorrect.