Commissioning – Lenze E82xVxxxKxxxxx User Manual

Page 216

Advertising
background image

Commissioning

Important codes for quick commissioning

8

l

216

EDS82EV903 EN 3.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0002
*

s

uSEr

(Cont.)

Transferring
parameter sets
with the
keypad

Keypad

ð PAR1 (+ FPAR1)

Overwrite selected parameter set
and, if required FPAR1, with the
corresponding data of the keypad

71

with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen

11

with all other function modules
Keypad

ð PAR2 (+ FPAR1)

72

with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen

12

with all other function modules
Keypad

ð PAR3 (+ FPAR1)

73

with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen

13

with all other function modules
Keypad

ð PAR4 (+ FPAR1)

74

with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen

14

with all other function modules
Controller

ð keypad

Copy all available parameter sets
(PAR1 ... PAR4, if required FPAR1)
into the keypad

80

with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen

20

with all other function modules
Keypad

ð function module

Only overwrite the
module−specific parameter set
FPAR1 with the data of the keypad

40

only with function module INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen

Function module

ð keypad

Only copy the module−specific
parameter set FPAR1 into the
keypad

50

only with function module INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen

C0002
*

s

uSEr

(Cont.)

Saving your
own basic
setting

9

PAR1

ð own basic setting

For the parameters of the
controller you can save an own
basic setting (e.g. the delivery
status of your machine):
1. Ensure that parameter set 1 is

active

2. Inhibit controller
3. Set C0003 = 3, confirm with

v

4. Set C0002 = 9, confirm with

v, the own basic setting is
saved

5. Set C0003 = 1, confirm with

v

6. Enable the controller

C0002
*

s

uSEr

(Cont.)

Loading/copyin
g the own basic
setting

By using this function you can also
just copy PAR1 into the parameter
sets PAR2 ... PAR4

5

own basic setting

ð PAR1

Restore own basic setting in the
parameter set selected

6

own basic setting

ð PAR2

7

own basic setting

ð PAR3

8

own basic setting

ð PAR4

Advertising