Mechanical installation

Standard devices with a power of 55 kW

Modification of the fan module for push−through technique

5

l

93

EDS82EV903−3.0

Plugging the fan connecting cable to another terminal on the fan module

9300vec173

Fig. 5−28

Plugging the fan connecting cable for the voltage supply to another terminal

1. Remove the cable lugs of the two red connecting cables and plug them in again on

the diagonally arranged side.

2. Remove the cable lugs of the two blue connecting cables and plug them in again on

the diagonally arranged side.

Mounting the fan module in a manner rotated by 180°

9300vec172

Fig. 5−29

Mounting the fan module on the controller

1. Place the fan module onto the controller. Insert the lugs at the back into the base

plate

0.

Make sure that the threaded sleeves do not touch the housing edge. They may break
off.

2. Push the fan module to the front.

3. Screw−in and fasten the 4 screws for fixing the fan module on each side.

4. Screw−in and fasten the two screws for the supply voltage.