Function library – Lenze E82xVxxxKxxxxx User Manual

Page 364

Advertising
background image

Function library

Display of operating data, diagnostics
Display of operating data

10

l

364

EDS82EV903 EN 3.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0322
(A)

Process
controller
output without
feedforward
control
(PCTRL1−OUT)

−650.00

{0.02

Hz}

650.00 Read only

C0323
(A)

Ramp function
generator
input
(NSET1−RFG1−
IN)

−650.00

{0.02

Hz}

650.00 Read only

C0324
(A)

Ramp function
generator
output
(NSET1−NOUT)

−650.00

{0.02

Hz}

650.00 Read only

C0325
(A)

PID controller
output
(PCTRL1−PID−
OUT)

−650.00

{0.02

Hz}

650.00 Read only

C0326
(A)

Process
controller
output
(PCTRL1−NOUT)

−650.00

{0.02

Hz}

650.00 Read only

C0500
*

Calibration of
process
variable −
numerator

2000 1

{1}

25000

l

Codes C0010, C0011, C0017,
C0019, C0037, C0038, C0039,
C0044, C0046, C0049, C0050,
C0051, C0138, C0140, C0181,
C0239, C0625, C0626, C0627
can be calibrated in a way to
make the keypad display a
process variable

l

If C0500/C0501 are changed,
the "Hz" unit is not shown in
the display anymore

^ 362

C0501
*

Calibration of
process
variable −
denominator

10

1

{1}

25000

C0500
*
(A)

Calibration of
process
variable −
numerator

2000 1

{1}

25000

l

Codes C0037, C0038, C0039,
C0044, C0046, C0049, C0051,
C0138, C0140, C0181 can be
calibrated in a way to make the
keypad display a process
variable in the unit selected in
C0502

l

Frequency−dependent codes
such as C0010, C0011, C0017,
C0019, C0050, C0239, C0625,
C0626, C0627 are always
provided in "Hz"

l

Changes in codes C0500 and
C0501 affect codes C0010 and
C0011; their values are scaled
correspondingly in the process

^ 362

C0501
*
(A)

Calibration of
process
variable −
denominator

10

1

{1}

25000

C0502
*
(A)

Unit − process
variable

0

0: Ċ
1: ms
2: s
4: A
5: V

6: rpm
9: °C

10: Hz
11: kVA
12: Nm

13: %
14: kW
15: N
16: mV
17: m

W

18:

W

19: hex
34: m
35: h
42: mH